(1) Independent water supply curtain cabinet air cooling unit maintenance cleaning and maintenance method
(1) Unit maintenance: pay attention to chassis cleaning, 15 minutes before switching on and off the machine should press the "clean" button on the control board for water cleaning (once a day) to prevent bacteria and odors.
(2) Unit cycle maintenance: the unit runs for 1-2 months, if the wet curtain, filter is blocked or the chassis is too dirty, in order to ensure the refrigeration effect should be cleaned in time, so as not to cause machine failure or affect its operation effect.
(3) Quarterly maintenance of the unit: If the unit runs for a long time, the air volume is small or the noise is too large, usually the external filter (evaporator wet curtain) is blocked, and the air cannot be entered, in this case, it is necessary to take out the three-sided water curtain cabinet cold air unit filter and the water curtain cabinet cold air unit side evaporator wet curtain paper directly with tap water to rinse the filter and cold air unit chassis.
(4) End-of-season maintenance: In order to prevent freezing damage to the body and mosquito breeding, when deactivating for a long time, the tap water should be closed, and then press the cleaning button to drain the water in the unit, take out the wet curtain paper of the evaporator on the side of the water curtain cabinet cold air unit and directly rinse the cold air unit chassis with tap water, and cut off the power supply.
(5) Pre-season maintenance: Before the start of the season, clean the external filter of the water curtain cabinet cold air cooler according to the above unit quarterly maintenance method, check whether there is any obstruction around the unit and the air inlet, and check whether the water level of the panel controller is normal after turning on the power supply.
(6) Water quality control: keep the water source clean, the pH of the water is between 6-9, the conductivity is less than 1000 ohms, regularly clean the pool, circulating water system, etc., to ensure that the water supply system is clean, keep the water supply quality good, in order to prevent the growth of algae or other microorganisms on the surface of the wet curtain, short-term treatment can be put into the water 3-5ppm chlorine or bromine. The concentration is 1 ppm (usually every half month) during continuous treatment.
(2) Maintenance and cleaning method of cold air cooling unit of central water supply water curtain cabinet
(1) Unit use and maintenance: pay attention to chassis cleaning, shut down the water curtain cabinet cold air unit system before the need to shut down the pump for 15 minutes and then shut down the fan, to ensure that the wet curtain is completely dried once a day, the water in the central water storage tank is used for 2 to 3 days (according to the cleanliness of the water in the water tank) need to clean the water tank and replace the water, in order to keep the water clean and clean, to prevent dirt in the water from blocking the water curtain water supply pipe hole, in order to prevent the growth of algae or other microorganisms on the surface of the water curtain, Short-term treatment involves the filling of chlorine dioxide or flower lotion (usually every half a month).
(2) Unit cycle maintenance: the unit runs for 1-2 months, if the wet curtain, filter is blocked or the chassis is too dirty, in order to ensure the refrigeration effect should be cleaned in time, so as not to cause machine failure or affect its operation effect.
(3) Quarterly maintenance of the unit: If the unit runs for a long time, the air volume is small or the noise is too large, usually the external filter (evaporator wet curtain) is blocked, and the air cannot be entered, in this case, it is necessary to take out the three-sided water curtain cabinet cold air unit filter and the water curtain cabinet cold air unit side evaporator wet curtain paper directly with tap water to rinse the filter and cold air unit chassis.
(4) End-of-season maintenance: In order to prevent freezing damage to the body and mosquito breeding, when deactivated for a long time, the tap water of the central water storage tank should be closed, and the wet curtain paper of the evaporator on the side of the water curtain cabinet cold air unit should be removed directly from the tap water to rinse the cold air unit chassis, and then the central water storage tank should be cleaned and drained, and the power supply of the fan and water pump should be cut off.
(5) Pre-season maintenance: Before the start of the season, clean the external filter and middle of the water curtain cabinet cold air cooler according to the above unit quarterly maintenance method
Central storage tank, check whether there are obstacles around the unit and the air inlet, and check whether the water level in the central storage tank is normal before opening the pump power supply.
(6) Water quality control: keep the water source clean, the pH of the water is between 6-9, the conductivity is less than 1000 ohms, regularly clean the pool, circulating water system, etc., to ensure that the water supply system is clean, keep the water supply quality good, in order to prevent the growth of algae or other microorganisms on the surface of the wet curtain, short-term treatment can be put into the water 3-5ppm chlorine or bromine. The concentration is 1 ppm (usually every half month) during continuous treatment.